All 57 Entries

The Joule Stack: Energy-Aware Computing from Database to Search

February 24, 2026 full-stack retrieval whitepaper uniting JouleDB (B-tree + 10,000-bit Kanerva hyperdimensional SDM), 28-provider float-free Verity search, 16-vendor Joule-LLM, an 11-layer cascade, and Three-Phase Energy Receipts.

David Charlot • • Addendum & Errata: Nov 25, 2026 • 6 min read • Glossary • Verification & AI-Use Disclosure
jouledb joule-search hyperdimensional-computing information-retrieval energy-receipts historical-whitepaper

Part I: Contemporary Historical Summary (As Written in February 2026)

Historical Source Provenance (Original Date: February 24, 2026): David Jean Charlot, PhD · Open Interface Engineering. Preserved from the February 24, 2026 joule-search / jouledb full-stack retrieval whitepaper.

Architecture: Five Systems Forming “The Circle”

Following our February 17, 2026 essay on polyglot database write amplification—where a single ingested document is routinely serialized five times across relational, full-text, vector, graph, and cache engines—the February 24, 2026 Joule Stack whitepaper specified five Rust 2024 components sharing a single energy-receipt protocol:

1. JouleDB        : 4 KB-page B-tree + `cf:name\x00key` column families + 10,000-bit Kanerva SDM / VSA
                    hyperdimensional associative index + IOKit/RAPL `OperationEnergyTracker`
2. Joule-Search   : "Verity" — 20 Rust crates, deterministic `QID = BLAKE3(RFC 8949 canonical CBOR)`,
                    float-free `u16` [0, 10000] fixed-point trust weights across 28 federated providers
3. Joule-LLM      : 16 direct-to-vendor inference adapters (incl. Groq LPU, Cerebras WSE-3, SambaNova RDU)
                    with `complete_eco()` circuit breakers & FLOP*PUE analytical remote estimators
4. Joule-Cascade  : 11-layer cognitive engine (L0-L4 execution ladder + L5-L10 damped meta-controllers)
5. Joule-WASM     : Browser-resident IndexedDB canonical CBOR store for zero-network offline recall

Float-Free Determinism & 28-Provider Corroborated Search (“Verity”)

IEEE-754 floating-point rankers can exhibit cross-architecture tie-breaking drift (x86_64 vs. AArch64 vs. wasm32 FMA contraction), breaking content-addressed cache equivalence. Verity (Joule-Search) normalized queries via QID = BLAKE3(canonical RFC 8949 CBOR) and scored results across 28 search providers (14 keyless open/academic indexes including Crossref, OpenAlex, ArXiv, PubMed, EuropePMC, Semantic Scholar, Wikidata, and Wikipedia + 14 commercial/web APIs) using u16 [0, 10000] integer basis points over a 9-dimensional trust vector (authority, recency, primary-source provenance, citation velocity, and cross-source corroboration, applying a +10% integer boost when independent academic and web indexes corroborated a claim).

The L0–L4 Execution Ladder & Three-Phase Energy Receipts

Across the L0–L4 execution tiers of Joule-Cascade (supervised by L5–L10 70/30 integer-damped threshold governors and session joule caps), the February 24 whitepaper reported typical per-step energy figures alongside their measurement phase:

Cascade LayerSubstrate / OperationTypical Per-Step Energy (Feb 2026)Three-Phase Receipt Field
L0 Exact QID CacheJouleDB B-tree + BLAKE3 CBOR hit~12 µJClient: MEASURED (RAPL / IOKit)
L1 Local BM25 + VSAEmbedded Tantivy + 10,000-bit Kanerva Hamming scan~890 µJClient: MEASURED (RAPL / IOKit)
L2 28-Provider FederationAsync HTTP/QUIC fan-out + late-interaction rerank~344,000 µJ (0.344 J)Client: MEASURED + Network: CALCULATED (14.4 nJ/B)
L3 LlmCheap SynthesisSmall/fast remote inference provider (complete_eco())~2,001,000 µJ (2.001 J)Remote: ESTIMATED (FLOP x PUE)
L4 Cross-Model AuditMulti-vendor verification on contested claims~4,000,000 µJ (4.000 J)Remote: ESTIMATED (FLOP x PUE)

Crucially, the Three-Phase Energy Receipt returned three disjoint fields on every query rather than summing incompatible telemetry sources:

  1. Client (MEASURED): Local host RAPL / NVML / hwmon / IOKit hardware energy counters (±5–10% counter tolerance);
  2. Network (CALCULATED): Payload wire bytes multiplied by a 14.4 nJ/byte transport boundary constant;
  3. Remote (ESTIMATED): active_watts × PUE × latency / batch_concurrency per remote accelerator class.

Methods, Epistemic Mapping & Licensing Scope Box (reported_j + est_j)

  1. Mapping February 2026 Three-Phase Receipts onto the November 2026 4-Class Lattice:
    • What the February 24 whitepaper called Client: MEASURED (RAPL / IOKit / NVML OS-exposed counters) corresponds in our November 2026 taxonomy to reported_j (on-chip counter telemetry), reserving measured_j strictly for external inline DC hardware shunts (INA226 / PowerZ / oscilloscope shunt benches). Both Network: CALCULATED (14.4 nJ/B, an analytical router/NIC intensity constant that varies widely across Wi-Fi, metro fiber, and submarine hops) and Remote: ESTIMATED (2.001 J and 4.000 J) belong to est_j.
    • Non-Mixing Note: Because ~12 µJ (L0 local reported_j amortized over warm batch lookups) and 2.001 J (L3 remote est_j) come from distinct epistemic classes, we report both numbers side-by-side with their provenance tags rather than claiming a single collapsed 166,750x physical-shunt ratio.
  2. Artifact & Licensing Status (BSL-1.1 / Private Core Mirrors): Public JouleDB binary releases and client interfaces at openIE-dev/jouledb are distributed under BSL-1.1 (Business Source License 1.1). The full underlying storage, HDC, and Verity federated-search Rust workspaces reside in private mirrors (openIE-dev/jouledb-core and openIE-dev/joule-search — externally unreproduced).

Chronological Evolution Within OpenIE Research

  1. Refining Three-Phase Receipts Into the 4-Tier Non-Mixing Law: Adding inline DC shunt benches (measured_j) on AMD Kria KV260 and NVIDIA Jetson Thor split physical board shunts above OS counters (reported_j), establishing measured_j ⊥ reported_j ⊥ est_j ⊥ unmetered.
  2. Storage Hardening & Multi-Model Benchmarks (JouleDB v0.1/v0.2 & Eco-Database): Tested unified Copy-on-Write storage physics against polyglot persistence pipelines.
  3. Bounding Federated Fan-Out Tail Energy (Eco-Knowledge & Latency): Examined when parallel 28-provider network fan-out wastes tail-straggler energy unless governed by deadline- and joule-aware hedged cancellation.
  • Kanerva, P. (1988). Sparse Distributed Memory. MIT Press; Kanerva, P. (2009). Hyperdimensional Computing: An Introduction to Computing in Distributed Representation with High-Dimensional Random Vectors. Cognitive Computation, 1(2), 139–159.
  • Harizopoulos, S., Liang, V., Abadi, D. J., & Madden, S. (2009). Energy Efficiency: The New Holy Grail of Data Management Systems Research. CIDR 2009 — early database-systems call for per-query joule accounting and energy-proportional storage.
  • Robertson, S., & Zaragoza, H. (2009). The Probabilistic Relevance Framework: BM25 and Beyond. Foundations and Trends in Information Retrieval, 3(4), 333–389 (implemented via Rust Tantivy).
  • Khattab, O., & Zaharia, M. (2020). ColBERT: Efficient and Effective Passage Search via Contextualized Late Interaction over BERT. SIGIR 2020.
  • Bormann, C., & Hoffman, P. (2020). RFC 8949: Concise Binary Object Representation (CBOR), Section 4.2 (Deterministic Encoding Requirements); O’Connor, J., Aumasson, J.-P., Neves, S., & Wilcox-O’Hearn, Z. (2020). BLAKE3: One Function, Fast Everywhere.

Changelog (2026-11-25)

  • Separated Part I (February 24, 2026 contemporary stack summary, removing anachronistic "today's" labels from Part I) from Part II (November 25, 2026 epistemic mapping, licensing provenance, and related work).
  • Explicitly documented BSL-1.1 licensing for public JouleDB binaries (openIE-dev/jouledb) and private repository status (unreproduced externally) for openIE-dev/jouledb-core and openIE-dev/joule-search.
  • Mapped the February Three-Phase Receipt fields onto reported_j vs. est_j without cross-class ratio mixing, and added citations to Kanerva (1988, 2009), Harizopoulos et al. (CIDR 2009), BM25 (2009), ColBERT (2020), RFC 8949 CBOR, and BLAKE3.
DC

David Charlot

Open Interface Engineering, Inc. · Signed Provenance · Self-Checked

JouleDB binaries/packages ship under BSL-1.1 at openIE-dev/jouledb, while full storage/search core sources reside in private mirrors (openIE-dev/jouledb-core and openIE-dev/joule-search — externally unreproduced). Full licensing & AI-use disclosure →

February 24, 2026 technical whitepaper; JouleDB binaries under BSL-1.1 at openIE-dev/jouledb; full core sources in private mirrors openIE-dev/jouledb-core & openIE-dev/joule-search (unreproduced externally)

Check the primary artifacts or run an independent replication

Inspect signed provenance manifests, rerun our public Apache-2.0 commodity-hardware replication kits, review our November 25, 2026 outside-review errata, or browse primary manuscripts on the Research Hub.