Minimum Energy Intelligence (MEI): 8-Year Coin-Cell Budget Math, -20 °C Brownout Simulation, and All Five Event Counts

Product/CAD simulation audit (est_j, 0 physical tags cycled): shows exact 8-yr 10 uW = 2.52 kJ vs CR2032 ~2.38 kJ cold-derated capacity math and reconciles 10,000 wakeups, 500 beacons, 490 refusals, 40/40 cold alerts, and 2,680 JCR-1 receipts.

MEI Coin-Cell Cold-Chain Simulation — 40/40 safety alerts preserved & 490/500 routine beacons refused in -20 °C simulation (2,680 JCR-1 receipts across 3 temps, est_j)
Datasheet/CAD cold-chain simulation (`est_j`): explicit `2.52 kJ` 8-year budget vs. `CR2032` derating and reconciled `10,000 / 500 / 490 / 40 / 2,680` event counts.

Temporal & Archival Scope: Era II OpenIE Study (November 22, 2026) · Canonical OpenIE Chronicle Entry: https://blog.openie.dev/posts/mei/ · Primary Paper & Methods: https://research.openie.dev/products/mei/ · Canonical Digest: blake3:tv:33f41b6dafca0a637986a28756e35c305743509289ac7774cfb84fcbc91804cb

Provenance & Telemetry Hygiene: Signed Provenance · Self-Checked (automated OpenIE internal gates; not externally peer-reviewed) · Energy Class: est_j (measured_j ⊥ reported_j ⊥ est_j ⊥ unmetered — Verification, Licensing & AI-Use Disclosure · Glossary & Non-Mixing Rules).

Key Claims & Evidence Tags

  1. [M/S · Explicit 8-Year Coin-Cell Arithmetic (est_j)] 10 uW × 8 yr × 3.15576 × 10^7 s/yr = 2,524.6 J ≈ 2.52 kJ (the primary review’s 9.9 uW STM32U3 + duty-cycled BME690 schedule spends 312 J/yr = 2,499 J over 8 yr). Candid battery gap: a standard 3.0 V, 220 mAh CR2032 holds ~2,376 J nominal (2,430 J at 225 mAh in cad-sim, 2,538 J at 235 mAh +21 °C datasheet) before ~1%/yr self-discharge and cold impedance derating (2,193 J usable to 2.0 V at +25 °C, 2,059 J at +4 °C, and 0 J unbuffered under 12 mA BLE TX pulses at -20 °C where internal resistance R_int jumps 6x from 12.0 ohm to 71.78 ohm, sagging terminal voltage to 1.951 V < 2.00 V brownout). True 8-year service therefore requires either < 5 uW duty-cycled sleep (5.1 uW with nRF54L15 = ~1.29 kJ over 8 yr) or a larger CR2477 / Li-SOCl2 primary cell plus a pulse buffer capacitor.
  2. [M/E · All Five Event Counts Reconciled (10,000, 500, 490, 40, 2,680)] Each simulated ambient trace (+25 °C, +4 °C, -20 °C) steps 10,000 scheduled sensor wakeups containing 500 routine BLE beacon attempts and 40 safety-critical temperature-excursion alert attempts (540 radio attempts/trace). At -20 °C, two-phase hold/settle grant sharding (35 mJ safety reserve) refuses 490 of 500 routine beacons (10 allowed) so 40 / 40 (100%) safety alerts succeed (vs. brownout collapse on an unsharded baseline). Because each allowed TX writes 2 JCR-1 receipts (hold + settle) and each refusal writes 1 receipt, the three traces emit 1,080 (+25 °C: 540 × 2) + 1,010 (+4 °C: 470 × 2 + 70) + 590 (-20 °C: 50 × 2 + 490) = 2,680 Ed25519-signed det-CBOR JCR-1 receipts.
  3. [M · Simulation Scope Disclosure] Every tag and campus-fleet number in mei comes from component datasheets (STM32U3, nRF54L15, BME690, Energizer CR2032) and discrete Python/Rust simulation (est_j, board_metered = false); no physical tag has undergone environmental chamber testing.

Methods, Baselines & Artifact Scope

8-Year Coin-Cell Energy Arithmetic & Cold-Chain Derating

Critique #6 flagged that 10 uW continuous power over 8 years exceeds a real CR2032 once derating is included. Showing the full ledger from src/content/products/mei.md confirms that critique [M, S]:

Reconciling All Five Simulation Event Counts (10,000 / 500 / 490 / 40 / 2,680)

The five integers in earlier summaries come from one accounting identity across the three simulated temperature traces (+25 °C, +4 °C, -20 °C) [E, M]:

Limitations & Chamber Validation Requirements

Energy & Telemetry Scope

Strictly est_j (board_metered = false, measured_j = null, reported_j = null), modeled from vendor datasheet curves.


Canonical Provenance, Primary Artifacts & Independent Replication